Environmental pilot testing is a process used to evaluate the effectiveness of environmental control technologies or strategies on a small scale before implementation on a larger scale. The purpose of pilot testing is to identify any issues or problems that may arise during implementation and to refine the technology or strategy to optimize its effectiveness.
This system can be used for a number of remediation processes such as Remediation Pilot testing, Soil Vapor Extraction (SVE) and Dual Phase Extraction (DPE).
These systems have different capabilities that are suitable for short-term and long-term operations and are ready to mobilize to your sites and obtain site-specific data for designing full-scale remediation systems.
Mobile Pilot testing system
Specifications
-Truck –Mounted High Vacuum Dual Phase Extraction System
-Brand: Solleco
-Model: 250 HVDPE
-Maximum Vacuum Pump Capability: 25 inch Hg
-Maximum Air Flow Rate: 250 CFM
-Utility Requirement: 3 Phase, 240 V
-Hydrocarbon Burning Tank and Exhaust system
-Knock-out Tank
-2 x 85 Gallon Dry Carbon Filtration Tanks
-A Kwiet 45 KVA Generator could be added to the system in some projects which has no access to the power utility